General
Get device info
Communication | Action | Parameter | Example |
---|---|---|---|
Request | 0 | ||
IP /0CXQRB2XQ3KD7XB/nexgentec.fcgi?action=0 |
|||
Reply | {“version”: “1.0.0”, “api-version”: “N3”,“fpga-version”: “2.2.0-d51c0cc4-#1040”, | ||
“serial”: “240818000117”,“type”: 1,“type-string”: “32140PWR”,“channel”: 32} |
Get host name
Communication | Action | Parameter | Example |
---|---|---|---|
Request | 1 | ||
IP /0CXQRB2XQ3KD7XB/nexgentec.fcgi?action=1 |
|||
Reply | {“hostname”: “My Amp”} |
Set host name
Communication | Action | Parameter | Example |
---|---|---|---|
Request | 2 | ||
IP /0CXQRB2XQ3KD7XB/nexgentec.fcgi?action=2&hostname=“MyAmp” |
|||
Reply | {“hostname”: “MyAmp”} |
Get IP configuration
Communication | Action | Parameter | Example |
---|---|---|---|
Request | 3 | ||
IP /0CXQRB2XQ3KD7XB/nexgentec.fcgi?action=3 |
|||
Reply | {“type”: “dhcp”,“ip”: “10.77.178.237”,“subnet”: “255.255.0.0”,“gateway”: “10.77.178.1”} |
Set IP configuration
Communication | Action | Parameter | Example |
---|---|---|---|
Request | 4 | ||
type=static/dhcp/auto | |||
ip=x.x.x.x | |||
netmask=x.x.x.x | |||
gateway=x.x.x.x | |||
IP /0CXQRB2XQ3KD7XB/nexgentec.fcgi?action=4&type=static&ip=10.77.178.10&subnet=255.255.0.0&gateway=10.77.178.1 |
|||
Reply | {“type”: “dhcp”,“ip”: “10.77.178.237”,“subnet”: “255.255.0.0”,“gateway”: “10.77.178.1”} |
Get mains voltage
Communication | Action | Parameter | Example |
---|---|---|---|
Request | 5 | ||
IP /0CXQRB2XQ3KD7XB/nexgentec.fcgi?action=5 |
|||
Reply | {“value”: 230} |
Set mains voltage
Communication | Action | Parameter | Example |
---|---|---|---|
Request | 6 | ||
value=90-240V | |||
IP /0CXQRB2XQ3KD7XB/nexgentec.fcgi?action=6&value=110 |
|||
Reply | {“value”: 110} |