symnet_config_destinations.toml
The destination config file describe the destinations which are identified by a Symetrix Symnet control number. If there is no Symetrix device present or SDM should not listen to Symetrix this file can be omitted
Caution
Use UNIX file fomatting when editing the file
Info
Generate yourself an example Generate example
See the fully commented definition below
- The file must be in TOML format
- Check the correct syntax online toml-lint
- Mandatory means that it will not work without.
# Defaults can be omitted if all values are defined destination specific.
# Destination object defined values are taking precedence
[default]
# Default delay settings for all objects that are not carrying its own settings for delay
# Object defined values are taking precedence , can be omitted
[default.delay]
# Delay value (ms) on disconnect, if omitted on object basis default settings apply
disconnect = 2000
# Default Symetrix settings for all objects that are not carrying its own settings for delay
# Object defined values are taking precedence, can be omitted
[default.symnet]
# Symetrix Site ID, defined in project settings, if omitted on object basis default settings apply
site_id = 2
# Symetrix DSP IP Address (v4), if omitted on object basis default settings apply
unit_ip = "127.0.0.1"
[[destination]]
# Name of the source or destination object, can be omitted
name = "MyDanteDestination_1"
[[destination.channel]]
# Dante channel name, mandatory for Dante devices
channel_name = "SDMD0000011"
# Channel index, if omitted the order of the channels below the object determines the index
index = 1
# Dante device name, can be omitted but should not.
node_name = "MyDanteDevice_1"
[[destination.channel]]
# Dante channel name, mandatory for Dante devices
channel_name = "SDMD0000012"
# Channel index, if omitted the order of the channels below the object determines the index
index = 2
# Dante device name, can be omitted but should not.
node_name = "MyDanteDevice_1"
# Object defined delay settings, if omitted on object basis default settings apply
[destination.delay]
# Delay value (ms) on disconnect, if omitted on object basis default settings apply
disconnect = 800
# Object defined Symetrix settings, mandatory
[destination.symnet]
# Symetrix Control Number for this destination object, mandatory
control_id = 5001
# Symetrix Control Number that is feed back to Symetrix once the destination has changed, can be omitted
feedback_id = 6001
# Symetrix Site ID, defined in project settings, if omitted on object basis default settings apply
site_id = 3
# Symetrix DSP IP Address (v4), if omitted on object basis default settings apply
unit_ip = "127.0.0.2"
[[destination]]
# Name of the source or destination object, can be omitted
name = "MyDanteDestination_2"
[[destination.channel]]
# Dante channel name, mandatory for Dante devices
channel_name = "SDMD0000021"
# Channel index, if omitted the order of the channels below the object determines the index
index = 1
# Dante device name, can be omitted but should not.
node_name = "MyDanteDevice_2"
[[destination.channel]]
# Dante channel name, mandatory for Dante devices
channel_name = "SDMD0000022"
# Channel index, if omitted the order of the channels below the object determines the index
index = 2
# Dante device name, can be omitted but should not.
node_name = "MyDanteDevice_2"
# Object defined delay settings, if omitted on object basis default settings apply
[destination.delay]
# Delay value (ms) on disconnect, if omitted on object basis default settings apply
disconnect = 800
# Object defined Symetrix settings, mandatory
[destination.symnet]
# Symetrix Control Number for this destination object, mandatory
control_id = 5002
# Symetrix Control Number that is feed back to Symetrix once the destination has changed, can be omitted
feedback_id = 6002
# Symetrix Site ID, defined in project settings, if omitted on object basis default settings apply
site_id = 3
# Symetrix DSP IP Address (v4), if omitted on object basis default settings apply
unit_ip = "127.0.0.2"